This flow control pulse transmitter module is designed to measure the continuous flow of liquids. The sensor produces a signal which can be transmitted and processed enabling the end user to get a flow measurement. Division is performed by measuring the pulses for the required unit of flow (litres per min.) and then, by the use of four rotary switches on the divider unit (discontinued) - that sit on top of the transmitter to divide signals enabling the output to be tailored to individual requirements. The correct dividing factor can be set up to give the required pulses out for the flow rate. If a fast flow is being monitored and the number of pulse outputs is extremely high the divider unit will bring this down to a more usable level and enable the measurement of any flow rate, regardless of PLC connected.Lower specification flow control transmitter module for use with PLCs. PNP or NPN output (use either depending on the PLC type. Interfaces via S030 pipework flow adaptor (see stock no. 249-7513 typically)Electrical Connection = Cable PlugControl Output = PNPMounting Style = CompactSupply Voltage = 12 - 36 V dcPipe Diameter Range = DN 6 - 65 mmMinimum Operating Temperature = -15°CMaximum Operating Temperature = +60°C