FGD-PDS-975UR 火焰探测器

品牌 Rosemount / Emerson 罗斯蒙特

分类 火焰探测器

  • 产品详情
  • 附件下载

Highly efficient dual band detector that is sensitive to UV and IR radiation, can be used indoors and outdoors to detect hydrocarbon-based flames with robust false alarm immunity.","Maximize Asset Coverage Eliminate blind spots and cost-effectively cover more of your facility Identify Abnormal Conditions Reliable flame detection coverage in any hazardous area provides a more holistic view of your facility Make the right decision when it counts — when safety is on the line Enhance safety and minimize trips to the field with accurate, real-time flame detection Specifications and Features Ultraviolet Infrared Design","Multiple output options for maximum flexibility and compatibility:","Automatic and Manual Built-In-Test (BIT):","Heated Window:","Approvals:

特性

  • 专为探测碳氢化合物燃料和气体火灾而设计
  • 特殊的逻辑电路,帮助防止由太阳辐射引起的假警报
  • Relays (3) for alarm, fault, and auxiliary 0–20 mA (stepped)
  • HART® Protocol for maintenance and asset management
  • rs-485,modbus兼容
  • 确保持续可靠运行
  • 消除冷凝和结冰
  • Hazardous Area – ATEX and IECEx, FM and CSA
  • Performance – EN54-10 (VdS), FM 3260
  • Reliability – IEC 615080- SIL 2 (TÜV)
  • Marine – MED 'Wheelmark' approval (DNV)
  • 专为探测碳氢化合物燃料和天然气火灾而设计的
  • 特殊的逻辑电路,有助于防止太阳辐射引起的错误警报
  • RS-485,Modbus兼容
  • 消除凝结和结冰

技术参数

规格项参数值
产品类型传感器
工作温度-67 to 185 F (-55 to 85 C)
输出选项模拟电流
用户接口选项计算机
特征可调延时
最大响应时间5.00 seconds
产品类别Flame Detectors
通信接口选项串口;其它
视场95/100
其他认证IP66 and IP67 per EN 60529, NEMA 250 6P, ATEX and IECEx, FM/FMC/CSA
测量技术仅紫外探测器
最大探测范围(灵敏度)215 ft (65.53 m)