Standard 800 Series metering flow switches are calibrated with water at approximately 25 °C \/ 77 °F. The use of fluids other than water may affect the accuracy of measurement due to differences in viscosity. Proteus' world-class calibration capability allows us to deliver instruments with specialized temperature- and fluid-specific calibration.","800 Series Metering Flow Switches","> Flow ranges from 0.2 to 227 LPM \/ 0.05 to 60 GPM > Liquid temperatures from -40 to 140°C \/ -40 to 284°F > Pressure to 1724 kPa \/ 250 psi > Calibrated 0–5 VDC output > Relay trip point – 16 preset settings > Compact design > 5-year warranty
技术参数
规格项 | 参数值 |
---|---|
液体体积流量 | 0.05 to 60.00 GPM (0.1894 to 227 L/min) |
电气输出 | Frequency |
安装 | In-line |
产品标准 | RoHS |
接口选项 | Serial/Digital |
产品类别 | Paddlewheel Flow Meters |
终端配件 | Threaded |
工作压力 | ? to 250 psi (? to 176 m H2O) |
仪表类型 | Volumetric Flow Meter |
测量介质 | Liquid |
介质温度 | -40 to 284 F (-40 to 140 C) |